Cold room cleaning and maintenance

Cold room cleaning is a regulatory obligation that falls directly within the scope of the «Hygiene Package», a set of three regulations governing food safety. Did you know that inadequate cleaning can encourage the proliferation of Listeria monocytogenes, a particularly resistant bacterium that thrives even in refrigerated environments?

Cold room maintenance is not just a matter of legal compliance, but also a major health and economic issue. It is recommended that you clean your cold room panels at least once a week with a disinfectant detergent suitable for food surfaces, while a thorough cleaning should be carried out annually. In addition, the cold room cleaning protocol must be carefully drawn up as part of your Sanitary Control Plan (SCP), a requirement that stems directly from European Regulation 852/2004.

This guide will explain in detail how to optimize the cleaning and maintenance of your cold rooms, the most effective methods to adopt, and the risks associated with poor maintenance. You'll also discover how to draw up a cold room cleaning plan tailored to your specific needs, and why regular checks on the tightness of the refrigeration system are imperative to prevent refrigerant gas leaks.

How does a walk-in cooler work?

To understand the importance of cleaning and maintaining cold rooms, it's essential to understand how they work. A cold room operates on the same principle as any conventional refrigeration equipment. It uses a refrigeration system consisting mainly of a compressor, condenser, evaporator and expansion valve to maintain a controlled temperature.

The difference between positive and negative cold rooms

There are two main types of cold room, each with its own specific maintenance requirements. The positive cold room maintains a temperature between 0°C and 10°C. They are particularly suitable for preserving fresh produce such as fruit, vegetables, dairy products or medicines, without freezing them. The reference temperature for this type of chamber is generally 3°C, although this may vary according to use.

In contrast, the negative cold room operates at temperatures below 0°C, usually around -18°C, but can be configured to reach much lower temperatures, down to -28°C. It requires greater insulation and fewer daily openings. This type of chamber is ideal for freezing foodstuffs, as negative cold solidifies the water contained in foodstuffs without damaging their cells.

Role of compressor, condenser, evaporator

The refrigeration cycle is based on four essential components working in harmony. Firstly, the compressor is the heart of the system. It compresses low-pressure, low-temperature refrigerant gas, transforming it into high-pressure, high-temperature gas. This compression increases the temperature and pressure of the refrigerant, creating the conditions necessary for the rest of the cycle.

Next, the condenser acts as a heat exchanger. Hot, high-pressure gas from the compressor enters the condenser, releasing its heat to the outside environment. This process cools the refrigerant, which then condenses into a high-pressure liquid. A fan usually blows air over the condenser coils to facilitate this heat transfer.

The liquid refrigerant then passes through the expansion valve, where its pressure is reduced, considerably lowering its temperature. Finally, in the evaporator, this cold refrigerant absorbs the heat present inside the cold room. Warm air is circulated around the evaporator coils by fans, allowing the refrigerant to evaporate as it absorbs this heat. As a result, the air cools and keeps the temperature low in the chamber.

Importance of the refrigerant

The refrigerant is the element circulating in this cycle, and its choice has a direct impact on the efficiency, operating costs and environmental impact of the cold store. Its main property is its ability to change state between liquid and gas at specific temperatures, thus facilitating heat transfer.

Historically, fluids such as R22 (chlorodifluoromethane) were commonly used. Today, more environmentally-friendly refrigerants are preferred, such as R134a for high-temperature systems or R404A for commercial refrigeration. Natural refrigerants such as ammonia (R717) and carbon dioxide (R744) are also gaining in popularity, thanks to their excellent thermodynamic efficiency and low environmental impact.

Understanding how a cold room works helps you to appreciate the importance of regular maintenance. An effective cold room cleaning protocol must take into account the specific features of each component to guarantee not only food safety, but also the energy efficiency and longevity of the installation.

Components to maintain regularly

Regular maintenance of the various components of a cold store not only guarantees its durability, but also optimizes its energy efficiency. Methodical, scheduled cleaning helps avoid costly breakdowns while maintaining ideal storage conditions. Let's take a look at the main elements requiring special attention.

Condenser: monthly cleaning

The condenser is a crucial component that requires monthly maintenance. A condenser clogged with dust or debris significantly reduces heat transfer efficiency. In particular, you should :

  • Check that the condenser fins are clean and free of dust
  • Make sure the cooling fan is working properly
  • Clean ventilation grilles for optimum air circulation

For effective condenser cleaning, use a soft brush, pressurized water or acid-free commercial foam cleaner. This will remove accumulated dirt and optimize the performance of your refrigeration system. In addition, clear any unnecessary debris from around the condenser to ensure proper ventilation. [1].

Evaporator: semi-annual cleaning

The evaporator requires thorough cleaning every six months. When clogged, this component can cause temperature variations and considerably reduce cooling capacity. To maintain its efficiency, you should :

  • Clean evaporator coils and fins
  • Check defrost system operation
  • Pay particular attention to the condensate drip tray and drain line.

Cleaning can be carried out using a brush, pressurized water or a specific evaporator cleaner. Never use acid-based products that could damage the equipment. [2]. Rinse thoroughly until no residue remains. A clean evaporator ensures better air circulation and optimum system efficiency, which has a direct impact on indoor air quality. [3].

Doors and seals: checking for leaks

Doors and door seals are the first barrier against cold loss. Regular inspections, ideally every three months, allow early detection of faults. Damaged or worn seals allow refrigerated air to escape, not only increasing operating costs, but also creating problems with food products that need to be kept at a specific temperature. [4].

  • During your cold room cleaning protocol, check :
  • No tears, cracks or deformations on joints
  • Correct alignment of doors and hinges
  • Operation of handles and locking mechanisms
  • Overall tightness by closing the door completely

Telltale signs such as cold air escaping, temperature fluctuations, increased electricity consumption or ice formation near the door frame usually indicate a sealing problem. [5]. Clean seals regularly with a mild detergent and a soft cloth to maintain flexibility and reduce the risk of cracking.

Fans and circuits: dust removal

Fans play an essential role in circulating cold air inside the room. Regular maintenance ensures even temperature distribution. During each inspection, make sure that :

  • Each fan turns freely and silently
  • Blades show no signs of wear or cracking
  • All motors are securely fastened to their support rail
  • Electrical circuits show no signs of deterioration

If a fan motor does not turn properly or makes an unusual noise, it must be replaced immediately. [2]. Check and retighten all fan adjustment screws if necessary. Dust build-up on these components can restrict airflow and increase compressor voltage, resulting in excessive energy consumption. [6].

A well-structured cold room cleaning plan, integrating the maintenance of all these components, not only helps to extend the life of your plant, but also ensures its optimal operation in all circumstances. The frequency of cold room cleaning must be adapted to the specific use and environment of your installation.

Effective cleaning methods

Effective cold room cleaning requires specific methods adapted to the low temperatures and materials involved. Appropriate techniques not only guarantee hygiene, but also the long-term preservation of refrigeration systems.

TACT method: temperature, action, chemistry, time

The TACT method is an essential systematic approach to any effective cold room cleaning protocol. This acronym stands for four interdependent factors:

  • Temperature: Cleaning efficiency doubles for every 10°C increase. A cleaner used at the optimum temperature (between 60°C and 80°C for certain products) offers better results.
  • Action: This is the mechanical force applied. For optimum cleaning, the water flow rate must be at least four times greater than that of the usual product.
  • Concentration: The correct dilution of cleaning products is crucial. Inadequate concentration leaves dirty surfaces that could contaminate the products.
  • Time: Time required depending on the type of equipment and method used. Insufficient time compromises cleaning efficiency.

These four factors interact with each other. An increase in one can compensate for a decrease in another, creating an optimal balance for high-performance cleaning.

Manual vs. high-pressure cleaning

There are two main approaches to positive cold room cleaning:

Low-pressure cleaning preserves water temperature better (loss of only 6°C at a distance of 50cm) and generates fewer aerosols. This method offers greater cleaning efficiency because it maintains the heat required to dissolve grease.

On the other hand, high-pressure cleaning (50 bar maximum at 30cm from the surface) should be used with caution. Nevertheless, it is effective in reaching hard-to-reach areas. Two methods are possible:

  • 1-step method: Simultaneous cleaning and vacuuming of dirty liquid.
  • 2-step method: Application of the product over the entire surface, followed by a second pass with vacuuming.

In addition, the use of hot water (maximum 60°C) facilitates the removal of organic soiling and speeds up drying, reducing downtime.

Use soft cloths and neutral soap

To preserve the integrity of insulated panels, it is imperative to use :

  • Non-abrasive cloths that won't damage surfaces
  • A pH-neutral soap (between 4 and 9) to prevent panel oxidation
  • Non-toxic cleaners, especially for food storage areas

Products containing chlorine should be avoided at all costs, and different cleaning agents should never be mixed. Steam cleaners are not recommended, as their high temperature can damage the coating.

Cold room cleaning protocol: key steps

An effective cold room cleaning plan follows this logical sequence:

  • Remove stored products or cover them if they are open foods
  • Always clean from top to bottom to avoid recontamination of surfaces
  • Rinse thoroughly with clean water
  • Apply diluted cleaner correctly (do not exceed recommended quantities)
  • Do not leave the solution in contact with the panels for more than 5 minutes
  • Remove residues with a non-abrasive cleaner
  • Rinse again with clean water
  • Make sure all surfaces are completely dry

This methodical approach guarantees not only cleaning efficiency, but also the preservation of equipment and the safety of stored products.

Risks associated with poor maintenance

Neglecting to maintain your cold room exposes your business to considerable risks, both health-wise and economically. An inadequate cold room cleaning protocol can have a number of serious consequences that deserve attention.

Bacterial proliferation (Listeria, etc.)

Contrary to popular belief, low temperatures do not stop all microbial growth. Listeria monocytogenes, for example, can thrive between -2°C and +4°C. [7]. Present in water and soil, this bacterium easily colonizes food processing environments. [7]. Indeed, poorly maintained cold rooms become ideal environments for its proliferation, particularly because of the humidity generated by condensation. [8]. Other micro-organisms can also multiply between 0°C and 2°C, contaminating your stored products. [8].

Cooling capacity losses

Insufficient maintenance directly compromises your system's performance. Ice build-up on evaporator coils blocks air circulation and reduces heat transfer efficiency. [9]. Even a slight deposit of ice can lead to a significant loss of efficiency. [9]. In addition, temperature fluctuations caused by faulty equipment can lead to the deterioration of stored products and significant financial losses. [10].

Overconsumption of energy

Neglected cold rooms consume more energy. A clogged condenser or inefficient refrigeration system forces the equipment to work harder to maintain the desired temperature. [11]. This overconsumption represents a considerable cost, given that electricity accounts for over 50% of the daily operating costs of a refrigeration system. [11]. In addition, premature component wear increases maintenance costs. [9].

Regulatory non-compliance

Failure to comply with hygiene standards may expose your company to administrative penalties. Cold stores must comply with strict food safety regulations, including temperature control and product traceability. [12]. An unfavourable inspection may result in fines or even the temporary closure of your establishment. [13]. A rigorous cold room cleaning plan is not just a question of hygiene, it's also a legal requirement.

Service and maintenance planning

A structured maintenance strategy ensures the efficiency and longevity of your cold store. An organized approach will prevent unexpected breakdowns and unnecessary costs.

Create a cold room cleaning plan

Any effective plan must precisely document procedures, products used and the responsibilities of each person involved. Incorporate data sheets detailing the cleaning steps specific to each area and equipment. You should also document positive and negative cold room cleaning protocols separately, as their requirements differ considerably.

Set up a maintenance schedule

Establish a rigorous schedule including :

  • Daily cleaning of contact surfaces
  • Weekly inspection of seals and doors
  • Monthly condenser maintenance
  • Quarterly defrosting and complete cleaning

Adapt the frequency of cold room cleaning to the intensity of use and the type of products stored.

Temperature monitoring

Install automated monitoring systems with deviation alerts. Keep all records for at least one year to ensure traceability and document compliance with HACCP standards. Perform daily manual checks to confirm instrument accuracy.

Calling on a certified professional

Some cold room maintenance operations require the intervention of qualified technicians, particularly when handling refrigerants or repairing electrical components. Choose service providers with recognized certifications and familiarity with your type of installation.

Conclusion

In the final analysis, rigorous maintenance of your cold store is much more than a simple administrative formality. This essential practice not only ensures regulatory compliance, but also the longevity of your facility and the safety of your stored products. Bacterial proliferation, particularly that of Listeria monocytogenes, is a real danger that only a meticulous cleaning protocol can prevent.

It's true that regular cleaning and maintenance require an investment of time and resources. However, compared to the potentially exorbitant costs of a major breakdown or food contamination, these efforts are more than justified. Think, too, of the energy savings achieved by an optimized refrigeration system - a clean condenser and tight door seals can cut your electricity bill considerably.

The TACT method (Temperature, Action, Concentration, Time) provides a structured framework for maximizing the efficiency of your cleaning operations. Combined with a precise maintenance schedule and systematic temperature readings, this approach enables you to maintain ideal storage conditions while extending the life of your equipment.

Don't forget that each component of your cold room deserves specific attention. Condensers, evaporators, door seals and fans all have their own maintenance intervals, which must be scrupulously respected.

A well-designed and rigorously applied cold room cleaning plan is therefore your best ally in guaranteeing food safety, energy efficiency and regulatory compliance. After all, the reliability of your cold chain depends directly on the quality of your maintenance.

FAQs

Q1. What is the recommended frequency for cleaning a cold room?

We recommend daily cleaning of contact surfaces, weekly inspection of seals and doors, monthly maintenance of the condenser and quarterly defrosting and thorough cleaning. Frequency may be adjusted according to use and type of products stored.

Q2. What are the key stages in an effective cleaning protocol for a cold room?

An effective protocol includes: removing stored products, cleaning from top to bottom, rinsing with clean water, applying a dilute cleaner, removing residues, rinsing again and drying surfaces thoroughly.

Q3. Why is it important to maintain a cold room regularly?

Regular maintenance prevents bacterial proliferation (such as Listeria), maintains energy efficiency, avoids loss of refrigeration capacity and ensures compliance with health regulations.

Q4. What are the risks associated with poor cold room maintenance?

Poor maintenance can lead to food contamination, excessive energy consumption, costly breakdowns, deterioration of stored products and administrative sanctions for non-compliance with hygiene standards.

Q5. Which cold room components require special attention during maintenance?

Key components to be regularly maintained are the condenser (monthly cleaning), the evaporator (half-yearly cleaning), doors and seals (leak check), as well as fans and circuits (dust removal).

References

[1] – https://www.heatcraftrpd.com/support/preventive-maintenance

[2] – https://www.uscooler.com/refrigeration-system-maintenance/

[3] – https://myddleton.co.uk/why-evaporator-coil-cleaning-is-crucial-for-business/

[4] – https://www.absolutecoldroom.co.uk/blogs/coldroom-advice/gaskets

[5] – https://airtightseals.com.au/coolroom-door-seals-or-gasket/?srsltid=AfmBOop6-yMeGD3NF13AwAhkj3Fc3yCV8EVYKoFvP3cQJFH4DzZfU5E5

[6] – https://www.frigosys.com/cold-room-faults-common-issues-and-troubleshootin/

[7] – https://www.pasteur.fr/en/medical-center/disease-sheets/listeriosis

[8] – https://www.burtonindustries.com.au/reasons-why-bacteria-can-grow-in-a-cool-room/

[9] – https://www.farrarscientific.com/blog/three-big-challenges-moisture-causes-in-cold-rooms

[10] – https://www.ajg.com/uk/news-and-insights/liability-risks-in-cold-storage-warehousing/

[11] – https://www.qtcoldstorage.com/cold-room-power-consumption/

[12] – https://www.microlistics.com/cold-storage-food-beverage/

[13] –https://www.bayareamechanicalservice.com/the-dangers-of-mold-and-bacteria-growth-in-walk-in-coolers/

Latest articles

Actualités
Certifications
Degreasing
Refrigeration systems
Energy optimization
Indoor Air Quality
Air treatment
Ultra-clean

More information on

our services & solutions?

Discover our solutions linked to this publication